You are currently not taking any of our courses.
Educate both your staff and your customers with our different courses!
Life demands more of our eyes which can be especially troubling for presbyopes who are already experiencing a loss of accommodation, reduced tear film stability, along with increased light scatter. Your presbyopic patients demand more from their contact lenses.
Introducing the multifocal contact lens your presbyopic patients have been waiting for - crisp and clear vision at all distances and lighting conditions±1 - plus all day comfort.#1
8.4 mm base curve/14.3 mm diameter
Power Ranges:
–9.00D to +6.00D (0.25D steps)
ADDs:
LOW: +0.75 to +1.25
MID: +1.50 to +1.75
HIGH: +2.00 to +2.50
Single usage: 1-day replacement
PUPIL OPTIMISED Design for Vision at All Distances2,8,9,10,11
TearStable™ Technology for All Day Comfort and Consistent Vision#1
OptiBlue™ Light Filter for Clarity in All Lighting Conditions±1
Proven on-eye performance in clinical trials§§:
± n=172 # n=378
* Versus ACUVUE® OASYS 1-Day
‡ Four total lenses
‡‡ Versus 1-DAY ACUVUE® MOIST MULTIFOCAL and ACUVUE® OASYS MULTIFOCAL
## Analysis involving one clinical study (n=35)
^ Filtering of HEV light by contact lenses has not been demonstrated to confer any systemic and/or ocular health benefit to the user. The Eye Care Professional should be consulted for more information.
†† Versus publicly available information for standard daily use contact lenses as of December 2023.
† Compared to competitor’s designs, technology optimized for both the parameters of refractive error and add power.
§ Versus DAILIES Total 1®, MyDay® and ULTRA® ONE DAY. Also significantly less than ACUVUE® OASYS 1-Day.
§§ Descriptive data from 4 clinical studies.
** All ACUVUE® contact lenses have Class 1 or Class 2 UV-blocking to help provide protection against transmission of harmful UV radiation to the cornea and into the eye. UV-absorbing contact lenses are NOT substitutes for protective UV-absorbing eyewear such as UV-absorbing goggles or sunglasses because they do not completely cover the eye and surrounding area. UV transmission measured with -1.00 lens.
1. JJV Data on File 2022: Subjective Stand-Alone Claims for ACUVUE® OASYS MAX 1-Day MULTIFOCAL Contact Lenses - Exploratory Meta-analysis.
2. JJV Data on File 2022. ACUVUE® PUPIL OPTIMIZED DESIGN Technology: JJVC Contact Lenses, Design Features, and Associated Benefits
3. JJV Data on File 2024: Stand-Alone Fit Success and Visual Acuity Claims for ACUVUE® OASYS MAX1-Day MULTIFOCAL Contact Lenses from a study of 136 completed subjects.
4. JJV Data on File 2022. TearStable™ Technology Definition
5. JJV Data on File 2023. Evaluation of Visual Artifacts with ACUVUE® OASYS MAX 1-Day MULTIFOCAL vs ACUVUE® OASYS MULTIFOCAL Contact Lenses.
6. JJV Data on File 2022. Effect on Tear Film and Evaluation of Visual Artifacts with ACUVUE® OASYS MAX 1-Day Family.
7. JJV Data on File 2022. Material Properties: 1-DAY ACUVUE® MOIST, 1-DAY ACUVUE® TruEye®, ACUVUE® OASYS 1-Day with HydraLuxe® Technology and ACUVUE® OASYS MAX 1-Day with TearStable™ Technology Brand Contact Lenses and other daily disposable contact lens brands.
8. JJV Data on file 2014. Report VIS-TD-101405 Analytical Comparison of of 1-DAY ACUVUE® MOIST® BRAND MULTIFOCAL CONTACT LENSES with LACREON® Technology to AIR OPTIX® AQUA Multifocal using MTF and Image Simulations.
9. JJV Data on file 2022: Report VIS-TD-107988/2 - Equivalency of the Safety and Effectiveness of the Optical Design across the ACUVUE® MULTIFOCAL PORTFOLIO.
10. JJV Data on file 2022: Report VIS-TD-108809/1 Designing Aurora to match the power profile of Lucy.
11. JJV Data on file 2022: Report VIS-TD-108817/1 Role of HEV Filters on Pupil Diameter: Aurora.
Important Safety Information: ACUVUE® Contact Lenses are indicated for vision correction. As with any contact lenses, eye problems, including corneal ulcers, can develop. Some wearers may experience mild irritation, itching or discomfort. Contact lenses should not be used in case of eye infections or any other eye conditions, or in case of a systemic disease that may affect the eye. For detailed product information, including contraindications, precautions and adverse reactions, please consult the Instructions for Use available on Johnson & Johnson website www.e-IFU.com.
2024PP16606
Material | Silicone Hydrogel (senofilcon A) |
Technology |
TearStable™ Technology |
Dk/t3 | 147 x 10-9 |
Water Content | 38% |
Approximate UV Blocking** | Class 1 | 100% UVB and 99.9% UVA |
Visibility Tint |
Yes | Blue-green Visibility Tint2 |
Inside-Out Mark | Yes |
Center Thickness (mm @ -3.00D) | 0.070 mm |
Available Pack Sizes |
30 Pack Carton (Rx) 90 Pack Carton (Rx) |
Instructions for Use |
± n=172 # n=378
** All ACUVUE® contact lenses have Class 1 or Class 2 UV-Blocking to help provide protection against transmission of harmful UV radiation to the cornea and into the eye. UV-absorbing contact lenses are NOT substitutes for protective UV-absorbing eyewear such as UV-absorbing goggles or sunglasses because they do not completely cover the eye and surrounding area. UV transmission measured with -1.00 lens.
1. JJV Data on File 2022: Subjective Stand-Alone Claims for ACUVUE® OASYS MAX 1-Day MULTIFOCAL Contact Lenses - Exploratory Meta-analysis.
2. JJV Data on File 2022. TearStable™ Technology Definition
3. Oxygen transmissibility measured via polarographic method at center -3.00D lens using boundary corrected, edge corrected Dk value. Units: (cm/sec) (ml O2/ml x mm Hg) at 35° C.
Important Safety Information: ACUVUE® Contact Lenses are indicated for vision correction. As with any contact lenses, eye problems, including corneal ulcers, can develop. Some wearers may experience mild irritation, itching or discomfort. Contact lenses should not be used in case of eye infections or any other eye conditions, or in case of a systemic disease that may affect the eye. For detailed product information, including contraindications, precautions and adverse reactions, please consult the Instructions for Use available on Johnson & Johnson website www.e-IFU.com.
2024PP16606
If your patient still has specific near or distance need, refer to the enhancement tables.
°° Appply vertex distance correction if greater than +/-4.00D
# n=378 ± n=172
1. JJV Data on File 2022: Subjective Stand-Alone Claims for ACUVUE® OASYS MAX 1-Day MULTIFOCAL Contact Lenses - Exploratory Meta-analysis.
Important Safety Information: ACUVUE® Contact Lenses are indicated for vision correction. As with any contact lenses, eye problems, including corneal ulcers, can develop. Some wearers may experience mild irritation, itching or discomfort. Contact lenses should not be used in case of eye infections or any other eye conditions, or in case of a systemic disease that may affect the eye. For detailed product information, including contraindications, precautions and adverse reactions, please consult the Instructions for Use available on Johnson & Johnson website www.e-IFU.com.
2024PP16606